Title: A behaviourally anchored rating scale for evaluating the use of the WHO surgical safety checklist: development and initial evaluation of the WHOBARS
Authors: Devcich, DA
Weller, J 
Mitchell, SJ 
McLaughlin, S
Barker, L
Rudolph, JW
Raemer, DB
Zammert, M
Singer, SJ
Torrie, J 
Frampton, CM
Merry, AF 
Keywords: WHO
WHOBARS
surgical safety checklist
SSC
checklists
operating rooms
Issue Date: Oct-2016
Source: Devcich DA, Weller J, Mitchell SJ, McLaughlin S, Barker L, Rudolph JW, Raemer DB, Zammert M, Singer SJ, Torrie J, Frampton CMA, Merry AF. A behaviourally anchored rating scale for evaluating the use of the WHO surgical safety checklist: development and initial evaluation of the WHOBARS. BMJ Qual Saf 2016;25(10): 778-86.
Abstract: BACKGROUND: Realising the full potential of the WHO Surgical Safety Checklist (SSC) to reduce perioperative harm requires the constructive engagement of all operating room (OR) team members during its administration. To facilitate research on SSC implementation, a valid and reliable instrument is needed for measuring OR team behaviours during its administration. We developed a behaviourally anchored rating scale (BARS) for this purpose. METHODS: We used a modified Delphi process, involving 16 subject matter experts, to compile a BARS with behavioural domains applicable to all three phases of the SSC. We evaluated the instrument in 80 adult OR cases and 30 simulated cases using two medical student raters and seven expert raters, respectively. Intraclass correlation coefficients were calculated to assess inter-rater reliability. Internal consistency and instrument discrimination were explored. Sample size estimates for potential study designs using the instrument were calculated. RESULTS: The Delphi process resulted in a BARS instrument (the WHOBARS) with five behavioural domains. Intraclass correlation coefficients calculated from the OR cases exceeded 0.80 for 80% of the instrument's domains across the SSC phases. The WHOBARS showed high internal consistency across the three phases of the SSC and ability to discriminate among surgical cases in both clinical and simulated settings. Fewer than 20 cases per group would be required to show a difference of 1 point between groups in studies of the SSC, where α=0.05 and β=0.8. CONCLUSION: We have developed a generic instrument for comprehensively rating the administration of the SSC and informing initiatives to realise its full potential. We have provided data supporting its capacity for discrimination, internal consistency and inter-rater reliability. Further psychometric evaluation is warranted.
URI: http://hdl.handle.net/11055/61
ISSN: 2044-5415
Appears in Collections:Scholarly and Clinical

Show full item record

Page view(s)

98
checked on Nov 24, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.