AIRR - ANZCA Institutional Research Repository
Skip navigation
Please use this identifier to cite or link to this item: https://hdl.handle.net/11055/804
Title: Increasing body mass index and abdominal subcutaneous fat thickness are associated with increased skin-to-epidural space distance in pregnant women
Authors: Eley, Victoria
Chin, Adrian
Sekar, Renuka
Donovan, Timothy
Krepska, Amy
Lawrence, Mitchell
Bell, Sheridan
Ralfem, Kate
McGrath, Shaun
Webb, Lachlan
Robinson, Alexander
van Zundert, Andre
Marquart, Louise
Keywords: Body Mass Index
Subcutaneous Fat, Abdominal
Cesarean Section
Epidural Space
Obesity
Parturition
Pregnancy
Analgesia, Epidural
Epidural
Abstract: BACKGROUND: Body mass index does not indicate the distribution of adipose tissue. Central adiposity may be measured using ultrasound measurement of subcutaneous fat thickness. This study determined if the abdominal subcutaneous fat thickness measured correlated with skin-to-epidural space distance at delivery, and compared this with the booking body mass index. METHODS: We analysed a sub-set of participants from a single-centre, prospective cohort study that assessed the relationship between subcutaneous fat thickness and maternity outcomes. Abdominal subcutaneous fat thickness measurements were obtained during the routine fetal anomaly scan. The skin-to-epidural space distance was obtained in those having epidural or combined spinal-epidural analgesia. Linear regression was used to test for strength of association and adjusted R2 values calculated to determine if subcutaneous fat thickness or body mass index was more strongly associated with skin-to-epidural space distance. RESULTS: The 463 women had a median (IQR) booking body mass index of 25.0 kg/m2 (21.8-29.3) and subcutaneous fat thickness of 16.2 mm (13.0-21.0). The median (IQR) skin-to-epidural space distance was 5.0 cm (4.5-6.0). Both parameters significantly correlated with skin-to-epidural space distance (r=0.53 and 0.68 respectively, P <0.001. Adjusted linear regression coefficient (95% CI) for subcutaneous fat thickness was 0.09 (0.08-0.11), R2=0.30 and for body mass index 0.12 (0.11-0.13), R2=0.47. CONCLUSIONS: Booking body mass index had a stronger relationship with skin-to-epidural space distance at delivery than subcutaneous fat thickness, explaining 47% of the variation in the skin-to-epidural distance.
URI: http://hdl.handle.net/11055/804
Appears in Collections:Scholarly and Clinical

Show full item record

Page view(s)

40
checked on Nov 19, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.